Products
TBC-DHS5 series current sensor provides accurate electronic measurement of DC, AC or pulsed currents. This series current sensor has rated current input between ±6 and ±50A, meansure range upto ±150A. It has 0.5% accuracy, very small size, very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±50AMax. Measuring Range :
±150AOutput Signal :
±0.625VSupply Voltage :
+5±5%Accuracy :
0.5%Op. Temperature :
-40 °C / 105 °CMounting :
Aperture Φ5.0mmWeight :
10gMOQ :
100
|
Electrical data(Ta=25℃±5℃) |
|
Type |
TBC06DHS5 |
TBC15DHS5 |
TBC25DHS5 |
TBC50DHS5 |
Unit |
|
Rated input (Ipn) |
±6 |
±15 |
±25 |
±50 |
A |
|
Measure range(Ip) |
±18 |
±45 |
±75 |
±150 |
A |
|
Secondary turns(Ns) |
960±1 |
960±1 |
960±1 |
960±1 |
T |
|
Internal resister |
25±0.1% |
10±0.1% |
6±0.1% |
3±0.1% |
Ω |
|
Rated output |
Ip=±Ipn ±0.625±0.5% |
V |
|||
|
Supply voltage |
+5±5% |
V |
|||
|
Power consumption |
≤15+Ip/Ns |
mA |
|||
|
Zero voltage |
@ Ip=0 2.5±0.4% |
V |
|||
|
Zero voltage drift |
@ -40~+105℃ ≤±0.05(Typ),≤±0.075(Max) |
mV/℃ |
|||
|
output drift |
@ -40~+105℃ ≤±0.05(Typ),≤±0.1(Max) |
mV/℃ |
|||
|
Linearity |
@ Ip=0-±Ipn ≤0.1 |
%FS |
|||
|
Total precision |
≤±0.7 |
% |
|||
|
di/dtaccuratelyfollowed |
>50 |
A/µS |
|||
|
Response time |
@ Ip=Ipn, 50 A/µS ,10%-90% <500 |
nS |
|||
|
Bandwidth |
@-3dB DC±100 |
KHz |
|||
|
Galvanic isolation |
@ 50HZ,AC,1min 2.5 |
KV |
|||
*Product updates, iterations, and parameter changes will not be notified separately
|
Applications |
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies(SMPS)
Power supplies for welding applications
Solar inverters
|
Mechanical dimension(for reference only) |

Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
|
Pin connections |
|
Turns |
Primary rated current |
Rated output |
Primary impedance |
Primaryinductance |
Connected points |
||
|
1 |
±6(±15, ±25,±50) |
2.5±0.625 |
0.18 |
0.013 |
|
||
|
2 |
±3(±7.5, ±12.5,±25) |
2.5±0.625 |
0.81 |
0.05 |
|
||
|
3 |
±2(±5, ±8.3,±16.6) |
2.5±0.625 |
1.62 |
0.12 |
|
||
|
Directions for use |
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
|
Further Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
|
Packing and Shipment |

Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City
Copyright @2023 Nanjing Token Electronics Science&Technology Co., Ltd. All Rights Reserved. Sitemap | Blog | Xml | Privacy Policy
Network Supported