Products
TBC-BTS4V series current sensor provides accurate electronic measurement of DC, AC or pulsed currents. This series current sensor has rated current input between ±50and ±300 meansure range upto ±600A. It has 0.5% accuracy, very small size, very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±300AMax. Measuring Range :
±600AOutput Signal :
±4VSupply Voltage :
±12 ~±18VAccuracy :
0.5%Op. Temperature :
-40 °C / ±105°CMounting :
Aperture 20.5x10.5mmWeight :
40gMOQ :
100
|
Electrical data(Ta=25℃±5℃) |
|
Type Parameter |
TBC50BTS4V |
TBC100BTS4V |
TBC150BTS4V |
TBC200BTS4V |
TBC300BTS4V |
Unit |
|
Rated input (Ipn) |
50 |
100 |
150 |
200 |
300 |
A |
|
Measure range(Ip) |
150 |
300 |
450 |
500 |
600 |
A |
|
Turns ratio(Np/Ns) |
1:1000 |
1:2000 |
1:1500 |
1:2000 |
1:3000 |
T |
|
Inside resistance |
20±0.1%,25PPM/℃ 0.5W |
20±0.1%,25PPM/℃ 0.5W |
10±0.1%,25PPM/℃ 1.0W |
10±0.1%,25PPM/℃ 1.0W |
10±0.1%,25PPM/℃ 1.0W |
Ω |
|
Rated output |
±4±0.5% |
V |
||||
|
Coil resister @70℃ |
20 |
30 |
30 |
3 |
50 |
Ω |
|
Supply voltage |
±12 ~±18 |
V |
||||
|
Power consumption |
≤20+IpX(Np/Ns) |
mA |
||||
|
Zero offset |
@Ip=0 ≤±30 |
mV |
||||
|
Zero drift |
@ -40~+85℃ ≤±0.5 |
mV/℃ |
||||
|
Linearity |
@Ip=0-±Ipn ≤0.1 |
%FS |
||||
|
Bandwidth |
@-3dB DC±100 |
KHz |
||||
|
Response time |
@100A/μS,10%-90% ≤1 |
μS |
||||
|
Galvanic isolation |
@ 50HZ,AC,1min 3 |
KV |
||||
*Product updates, iterations, and parameter changes will not be notified separately
|
Applications |
AC variable speed drives
Static converters for DC motor drives
Variable speed drives
Power supplies for welding applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies(SMPS)
|
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
|
Directions for use |
1. When measure current flows according to the direction of the arrowhead, Output terminal gets the same phase current.
2. When the current will be measured goes through a sensor, the current will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
3. Custom design in the different rated input current and the output current are available.
|
Further Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
|
Packing and Shipment |

Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City
Copyright @2023 Nanjing Token Electronics Science&Technology Co., Ltd. All Rights Reserved. Sitemap | Blog | Xml | Privacy Policy